7032A-L Loop Autosampler
The 7032A-L Autosampler automates the introduction of up to 21 samples into a gas chromatograph for quantitative analysis. Fixed volume loops are used to measure and equilibrate sample volumes to atmospheric pressure before injection to the GC. Small sampling containers, called MiniCans, are used to collect the sample in the field using the self contained vacuum to pull a 400cc volume into the fused silica lined interior. The inert inner surface permits sample stability for days or even weeks. Vacuum rated mini-quick connects allow initial vacuums to be maintained in the MiniCan for months before sampling, and allows “tool-free” sampling in the field. The vacuum driven sampling eliminates the need for pumps or electrical power.
Variable Volume Injections
The 7032A-L uses an electronic splitter to adjust the actual volume of sample delivered to a GC. Using a single loop, the volume can be split as much as 100:1 allowing a greater range of sample concentrations to be analyzed without dilution. Variable injection volumes also allow calibration curves to be generated from a single calibrated standard cylinder. Constant internal standards can be added independent of sample or analytical standard volumes.
Surrogate Spiking
The 7032A-L can perform automated pressurization of MiniCans before attachment to the 21 position inlet. Two modes support either a targeted final pressure or a dilution factor of 1.5x, 2x, or 3x. By attaching a cylinder containing a surrogate standard to the pressurizing gas inlet, a known amount of surrogate can easily be added to each MiniCan. Quantifying the amount of surrogate recovered provides verification of proper recovery of sample, a feature that is unique to the 7032A-L.
Large Volume Preconcentration
The 7032A-L is also available without a loop injection valve (Model 7032A) for operation with the 7100A Preconcentrator. Instead of being limited to a maximum of 5cc, the 7100A/7032A Preconcentration system allows recovery of 10-1000cc, depending on the initial pressure of the 400cc MiniCan. This greatly enhances detection limits allowing the analysis of compounds in the 1-1000 ppb range.
Focusing Option
Applications
Industrial Hygiene Stack
Landfill Gas Product
Environmental Chambers
Mobile Laboratories
Petroleum/Petrochemical
Emergency Response Programs
Gas
Offgasing
Breath Analysis
Indoor Air
Soil Gas
Remote Head Space
Ordering Information
Description Part Number
21 Position Loop Injection Auto sampler 7032A-L
21 Position Autosampler for Operation with 7100A 7032A
Electronic Splitter 7032-01
Focusing Option 7032-02
MiniCan Heater 09-70100
Silonite™ Lined 400cc MiniCan Canisters 29-MC400L
Applications
|
|
-
Gas
-
Offgasing
-
Breath Analysis
-
Indoor Air
-
Soil Gas
-
Remote Head Space
|
Ordering Information |
Part Number |
Description |
7032A-L |
21 Position Loop Injection Auto sampler |
7032A |
21 Position Autosampler for Operation with 7100A |
7032-01 |
Electronic Splitter |
7032-02 |
Focusing Option |
09-70100 |
MiniCan Heater |
29-MC400L
|
Silonite™ Lined 400cc MiniCan Canisters |
|